Friday, June 18, 2010

Re: Insteon PLM feedback

0 comments
I did more test and the problem I found is the PLM send a echo of the
command before sending the ack follow by the feedback.
ex 02 62 07 98 B6 0F 11 FF 06 02 50 07 98 B6 0F 9C E2 2B 11 FF
---------command On------- ack -----------------
status-----------------------

If the regex is the command \x02\x62\x07\x98\xB6\x00\x11\(\x00)?
(\xFF)? it works. But it's not the status
Iviewer does not receive any feedback just the echo ?

On 18 juin, 13:50, Jarrod Bell <jar...@guilink.com> wrote:
> Try setting EOM to \x06 because every message that comes back ends
> with \x06 if it was successful right?
> Are there any unsolicited commands that are sent automatically, that
> would not contain an ACK (\x06) ?
>
> Then try regex:
> \x07\x98\xB6\x0F\9Cx\E2\x20\x11(\x00)?(\xFF)?
>
> Then adjust your "On" capture group to point to 'capture index = 2'
> and on value = \xFF  - note above you wrote x\ instead of \x, make
> sure you enter \x
>
> Let me know if that works.
>
> Jarrod
>
> On Jun 18, 10:58 pm, Samtronic <samtroni...@gmail.com> wrote:
>
>
>
> > Hi !
>
> > I have a Insteon powerlinc modem serial (PLM 2412s) for lighting. The
> > PLM can send RS-232 command. Here some linkshttp://www.madreporite.com/insteon/commands.htmhttp://www.aartech.ca/....
>
> > My problem is the feedback. I receice no feedback. I configure button
> > On and Off.
>
> > Command value for On: \x02\x62\x07\x98\xB6\x00\x11\xFF
>
> > \x02 All command start with
> > \x62 Insteon standard message
> > \x07\x98\xB6 Address of the switch
> > \x00 Flag
> > \x11 command 1 ON
> > \xFF command 2 Level 255
>
> > Command value for Off: \x02\x62\x07\x98\xB6\x00\x11\x00
>
> > x00  Level 0 Off
>
> > Commands works well , but I don't know for carriage return, If a put
> > \x0D the command doesn't work.
> > After the command the PLM  should send this command: \x02\x50x
> > \x07\x98\xB6\x0F\x9C\x\E2\x20\x11\xFF or \x00
>
> > \x02 All command start with
> > \x50 IM command number
> > \x07\x98\xB6\  switch address
> > \x0F\x9C\x\E2 PLM address
> > \x20 flag
> > \x11 comman 1 ON
> > \xFF or \x00  Level
>
> > With Docklight I receive this command:
>
> > 2010-06-17 22:50:03.556 [RX] - 02 62 07 98 B6 0F 11 FF 06 02 50 07 98
> > B6 0F 9C E2 2B 11 FF
>
> > x\06 ack
>
> > I try different regex with no success. The last I try is this regex
> > .*\x07\x98\xB6\x0F\9Cx\E2\x20\x11(\x00)?(\xFF)?
> > I just keep the last digits. It is ok ?
>
> > Feedback configuration
>
> > Name                    On
> > Capture index   1
> > Data type               Digital
> > Target type     Digital
> > Join                    200
> > Token type
> > Off value
> > On value                x\FF
>
> > Name                    Off
> > Capture index   1
> > Data type               Digital
> > Target type     Digital
> > Join                    201
> > Token type
> > Off value
> > On value                x\00
>
> > System configuration
> > Maintain constant connection
> > No heartbeat
> > No EOM
>
> > I create this regex (.*) to see the data come in and I receice some
> > character like P b. I think it's ASCII.
>
> > Thanks
>
> > Steven
> > P.S sorry for my english

--
You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.

Comments

0 comments to "Re: Insteon PLM feedback"

Post a Comment

 

Copyright 2008 All Rights Reserved Revolution Two Church theme by Brian Gardner Converted into Blogger Template by Bloganol dot com