EOM. Even the slider works flawlessly.
Thanks for your help.
Steven
On 18 juin, 19:55, Samtronic <samtroni...@gmail.com> wrote:
> I did more test and the problem I found is the PLM send a echo of the
> command before sending the ack follow by the feedback.
> ex 02 62 07 98 B6 0F 11 FF 06 02 50 07 98 B6 0F 9C E2 2B 11 FF
> ---------command On------- ack -----------------
> status-----------------------
>
> If the regex is the command \x02\x62\x07\x98\xB6\x00\x11\(\x00)?
> (\xFF)? it works. But it's not the status
> Iviewer does not receive any feedback just the echo ?
>
> On 18 juin, 13:50, Jarrod Bell <jar...@guilink.com> wrote:
>
>
>
> > Try setting EOM to \x06 because every message that comes back ends
> > with \x06 if it was successful right?
> > Are there any unsolicited commands that are sent automatically, that
> > would not contain an ACK (\x06) ?
>
> > Then try regex:
> > \x07\x98\xB6\x0F\9Cx\E2\x20\x11(\x00)?(\xFF)?
>
> > Then adjust your "On" capture group to point to 'capture index = 2'
> > and on value = \xFF - note above you wrote x\ instead of \x, make
> > sure you enter \x
>
> > Let me know if that works.
>
> > Jarrod
>
> > On Jun 18, 10:58 pm, Samtronic <samtroni...@gmail.com> wrote:
>
> > > Hi !
>
> > > I have a Insteon powerlinc modem serial (PLM 2412s) for lighting. The
> > > PLM can send RS-232 command. Here some linkshttp://www.madreporite.com/insteon/commands.htmhttp://www.aartech.ca/....
>
> > > My problem is the feedback. I receice no feedback. I configure button
> > > On and Off.
>
> > > Command value for On: \x02\x62\x07\x98\xB6\x00\x11\xFF
>
> > > \x02 All command start with
> > > \x62 Insteon standard message
> > > \x07\x98\xB6 Address of the switch
> > > \x00 Flag
> > > \x11 command 1 ON
> > > \xFF command 2 Level 255
>
> > > Command value for Off: \x02\x62\x07\x98\xB6\x00\x11\x00
>
> > > x00 Level 0 Off
>
> > > Commands works well , but I don't know for carriage return, If a put
> > > \x0D the command doesn't work.
> > > After the command the PLM should send this command: \x02\x50x
> > > \x07\x98\xB6\x0F\x9C\x\E2\x20\x11\xFF or \x00
>
> > > \x02 All command start with
> > > \x50 IM command number
> > > \x07\x98\xB6\ switch address
> > > \x0F\x9C\x\E2 PLM address
> > > \x20 flag
> > > \x11 comman 1 ON
> > > \xFF or \x00 Level
>
> > > With Docklight I receive this command:
>
> > > 2010-06-17 22:50:03.556 [RX] - 02 62 07 98 B6 0F 11 FF 06 02 50 07 98
> > > B6 0F 9C E2 2B 11 FF
>
> > > x\06 ack
>
> > > I try different regex with no success. The last I try is this regex
> > > .*\x07\x98\xB6\x0F\9Cx\E2\x20\x11(\x00)?(\xFF)?
> > > I just keep the last digits. It is ok ?
>
> > > Feedback configuration
>
> > > Name On
> > > Capture index 1
> > > Data type Digital
> > > Target type Digital
> > > Join 200
> > > Token type
> > > Off value
> > > On value x\FF
>
> > > Name Off
> > > Capture index 1
> > > Data type Digital
> > > Target type Digital
> > > Join 201
> > > Token type
> > > Off value
> > > On value x\00
>
> > > System configuration
> > > Maintain constant connection
> > > No heartbeat
> > > No EOM
>
> > > I create this regex (.*) to see the data come in and I receice some
> > > character like P b. I think it's ASCII.
>
> > > Thanks
>
> > > Steven
> > > P.S sorry for my english
--
You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.


Comments