Yes, in the command you want to send, replace the last byte with the
string [sliderval]
Then set the slider to send the command, and set it to hex mode in
slider properties.

See our wiki for more info:
http://www.commandfusion.com/wiki/index.php?title=Command#Assigning_Commands_to_Sliders

Jarrod

On Aug 4, 3:38 pm, NZ <e...@clear.net.nz> wrote:
> Unsure if this is even a possibility but before I waste  a lot of time
> I thought id find out,
> A dimmer, responds to serial, (Via a GC100)
> the commands range from
> \xFE\x4C\x42\x01\x01 for minimum, to
> \xFE\x4C\x42\x01\xFA for maximum, using the first 4 bytes as a
> constant, can I use a gauge, with an analogue join, to simulate the
> last byte? Or even Up down arrows to modify the byte in increments? or
> do I just have to go back to "dim", "bright" buttons?
>
> Any Ideas Appreciated
> Cheers in advance,
>
> Nic

--
You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.