This is an example of a capture from the GC-IRL:
sendir,5:3,182,40000,1,1,96,23,48,22,24,23,24,23,24,23,24,23,48,22,24,23,24,23,24,23,24,23,24,23,48,22,48,22,24,23,24,803
Remember to terminate your commands with CR or LF characters as
required. . .
On 06/07/2010 17:47, Rodrigo Drumond wrote:
> Thank's Ivan
>
> see the code generated by the converter:
>
> sendir,<mod-addr>:<conn-addr>,11,38000,<repeatcount>,1,172,170,20,18,20,18,20,18,20,18,20,18,20,55,20,18,20,18,20,18,20,
> 18,20,18,20,18,20,18,20,18,20,18,20,18,20,170,20,55,20,55,20,55,20,18,20,18,20,18,
> 20,55,20,18,20,55,20,18,20,18,20,18,20,55,20,55,20,18,20,55,20,18,20,55,20,55,20,55,20,2199
>
> What is 'repeatcount' (red) ?
>
> I sent the code above with the program 'Test Utility', but the IR
> emitter did not blink.
> What can i do ?
>
>
>
>
> On Tue, Jul 6, 2010 at 12:31 PM, Ivan Craig <ivancrg240@gmail.com
> <mailto:ivancrg240@gmail.com>> wrote:
>
> Hi Rodrigo
>
> Use the CCF convert utility from GC.
>
> Copy your CCF code to the CCF window with "CCF to GC-100" button
> selected. Click Convert.
>
> Copy the text from the GC-100 Command window to a text editor
> (Notepad)
>
> Change the <mod-addr> to 2. This is the module address of the IR
> outputs on a GC-100-6.
>
> Change the <conn-addr> to the IR number – if you have the IR cable
> plugged into the left most IR socket then its address will be 1.
>
> Your command will look something like this (shortened for clarity)
>
> sendir,2:1,2,38000,1,1,129,62,17,14,17,14,17,46,17,14,17,46,17,14,17,46,17,14,17,14,17,46,17,14,17,14,17,46,17,46
>
> go to the end of the line and add \x0d
>
> sendir,2:1,2,38000,1,1,129,62,17,14,17,14,17,46,17,14,17,46,17,14,17,46,17,14,17,14,17,46,17,14,17,14,17,46,17,46\x0d
>
> Go to command fusion and make sure that you have the a GC-100 in
> the system manager with IP address set correctly
>
> Create a new command in this system. In the command value field
> copy and paste the string from your text editor.
>
> *If it does not work*
>
> 1 Make sure you have set the system properties for the GC-100 in
> system manager correctly.
>
> 2 Create a digital join to verify that the system is connected.
>
> 3 When you send the command, look at the LED on the GC-100
> ehternet connection – it should flash each time you press the
> button in iViewer. If not you have a system setting problem
>
> 4 If above is ok then look at the IR led at the back of the GC100.
> This should flash each time a command is sent. If not, check out
> your command for errors.
>
> 5 If above is ok then your CCF code needs checking.
>
> 6 Still not working – switch off and try tomorrow
>
> Regards
>
> *From:* commandfusion@googlegroups.com
> <mailto:commandfusion@googlegroups.com>
> [mailto:commandfusion@googlegroups.com
> <mailto:commandfusion@googlegroups.com>] *On Behalf Of *Rodrigo
> Drumond
> *Sent:* 06 July 2010 03:56 PM
> *To:* commandfusion@googlegroups.com
> <mailto:commandfusion@googlegroups.com>
> *Subject:* GC-100 -
>
> Hi,
> Someone have a command example to send to Global Caché GC-100?
> I'm not understanding the integration with the command Fusion
> I have here:
>
> Codes in the format CCF
> The program "Converter", from Global Caché
> GC-100 -06
>
> I just need an example *:*)
>
>
>
> --
> Rodrigo Drumond
> Certified for Philips Pronto products
> Phone: +55 31 3377-3150
> Mobile: +55 31 8699-2549
> www.quantaautomacao.com.br <http://www.quantaautomacao.com.br>
>
> --
> You received this message because you are subscribed to the Google
> Groups "CommandFusion" group.
> To post to this group, send email to
> commandfusion@googlegroups.com
> <mailto:commandfusion@googlegroups.com>.
> To unsubscribe from this group, send email to
> commandfusion+unsubscribe@googlegroups.com
> <mailto:commandfusion%2Bunsubscribe@googlegroups.com>.
> For more options, visit this group at
> http://groups.google.com/group/commandfusion?hl=en.
>
> --
> You received this message because you are subscribed to the Google
> Groups "CommandFusion" group.
> To post to this group, send email to
> commandfusion@googlegroups.com
> <mailto:commandfusion@googlegroups.com>.
> To unsubscribe from this group, send email to
> commandfusion+unsubscribe@googlegroups.com
> <mailto:commandfusion%2Bunsubscribe@googlegroups.com>.
> For more options, visit this group at
> http://groups.google.com/group/commandfusion?hl=en.
>
>
>
>
> --
> Rodrigo Drumond
> Certified for Philips Pronto products
> Phone: +55 31 3377-3150
> Mobile: +55 31 8699-2549
> www.quantaautomacao.com.br <http://www.quantaautomacao.com.br>
> --
> You received this message because you are subscribed to the Google
> Groups "CommandFusion" group.
> To post to this group, send email to commandfusion@googlegroups.com.
> To unsubscribe from this group, send email to
> commandfusion+unsubscribe@googlegroups.com.
> For more options, visit this group at
> http://groups.google.com/group/commandfusion?hl=en.
--
You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.