As you can see from the image the joins go from 901 to 912 so I also kept a sequence.
On 7/20/2010 9:54 PM, Nahshon Williams wrote:
Hmmm. . .
Need more info.
I assume you are using a different protocol to the wiki example, if so please post the regex and response you are expecting/getting.
At present I have an onkyo on this "either or" function based on frequency matches.
Here is how I got mine to work:
Ecpected Data when station changed or queried from Onkyo: ISCP!1TUN08880
Regex: .*!1TUN(09850)?(08880)?(09130)?(09350)?(10490)?(09490)?(10620)?(10090)?(10220)?(10540)?(09730)?(09580)?.*
Too lazy to type the rest so here is an image:
http://vandermehrn.com/lc/onkyo/WhichStation.png
What the image shows is the different capture groups and relevant station.
Here you can see BBC Radio 2 is on the frequency above.
They are digital joins and there is no off value.
Simulate feedback is switched off (as this is the real deal)
hope this helps. . .
Nahshon
On 7/20/2010 9:14 PM, Waldy,,,, Liverpool Uk wrote:Hi Nashon, Have finally got around to setting this up and have come up with a problem. I have the digital joins set for 5 preset radio stations, the join no's are 950-954. i used this range as I am trying to keep pages in sequence. I have followed the instructions and when I do the regex test the join number picks out the correct group. However nothing now happens when I press the button. It does not even execute the command to pick the radio channel. Any idea what could be wrong thanks Waldy