Hi Jarrod !

I use Eventghost for controlling XBMC, MPC-HC on my HTPC. In the
project properties, I configured the ip address of my HTPC, port 456,
connection join 0, Enable debug mode don't thick. It works well with
Eventghost. For the system manager I configured one System for the
Denon. It's the ip address of my server, where the TCP2SERIAL
application runs 24h. Port 888, TCP thick,maintain constant connection
thick,
Heartbeat manage by system don't thick, heartbeat TX RX nothing, OEM
nothing, connection join 0, startup cmd none.

Thank you for your help

Samtronic

On 24 mar, 09:32, Jarrod Bell <jar...@guilink.com> wrote:
> Can you please list all the properties you have set for every system
> in system manager?
> Or are you using EventGhost and our plugin with connection details set
> in the project properties?
>
> Jarrod
>
> On Mar 24, 11:24 pm, Samtronic <samtroni...@gmail.com> wrote:
>
>
>
> > Hi!
>
> > First of all thank for this tuto. I have a problem with de guage. In
> > the feedback properties I put this regex MV(\d*)\x0D. I try this one
> > ^MV(\d*)\x0D$ , but it does not work.
> > My problem is that the gauge is erratic. When I press volume down or
> > up, sometime it works, but most of the time the gauge does not respond
> > well.
> > it goes completly up or down. I use TCP2Serial on my computer to
> > control my Denon 2307ci.
>
> > Thanks
> > Samtronic
>
> > P.S sorry for my english
> > On 3 mar, 22:19, Fiasco <dgvoll...@gmail.com> wrote:
>
> > >http://scores.warbirdsiii.com/onkyors232.xls
>
> > > On Mar 3, 6:27 pm, Fiasco <dgvoll...@gmail.com> wrote:
>
> > > > I'll upload it and post a link later tonight
>
> > > > On Mar 3, 1:38 pm, Nahshon Williams <spc...@gmail.com> wrote:
>
> > > > > Fiaso, it is on your enthusiasm that I have elected to get the onkyo.  
> > > > > Where can I find their protocol? Could you email me a copy?
> > > > > I am currently working on an "apple style" remote for the onkyo for now
> > > > > just the images and buttons.
> > > > > I emailed onkyo (no response yet).  Downloaded the 156 page manual for
> > > > > the tx-nr-5007 but no mention of the protocol.
> > > > > The unit is difficult to find in London. The shop keeps telling me they
> > > > > will be in stock soon. I hope it is worth the wait. . .
>
> > > > > On 03/03/2010 19:13, Fiasco wrote:
>
> > > > > > Love my Onkyo 875.   RS232 protocol is fantastic and I run all three
> > > > > > zones through command fusion.
>
> > > > > > On Mar 3, 4:50 am, Nahshon Williams<spc...@gmail.com>  wrote:
>
> > > > > >> I have not yet finished the project :-(                        
> > > > > >> (Thinking of moving to onkyo as zones not working on thisdenon)
>
> > > > > >> Anyway here is how I was able to get feedback working.
>
> > > > > >> Here are the images that I use:  http://vandermehrn.com/lc/feedback/
>
> > > > > >> Everything lies in the REGEX.
> > > > > >> Things to note.
>
> > > > > >> You do not need to escape the "\" in "\x0D" EXCEPT when testing your
> > > > > >> regex in the regex tester. (no quotes in regex)
>
> > > > > >> For example to get feedback on the guage for volume, I send thedenon;
>
> > > > > >> MVUP\x0D
>
> > > > > >> Thedenonresponds with
>
> > > > > >> MV50\x0D . . . MV51\x0D. . .MV52\x0D. . .MV53\x0D and so on as long as
> > > > > >> it gets a new "volume up" command it will respond with the new change in
> > > > > >> value.
>
> > > > > >> A regex to capture this would be ^MV(\d*)\x0D$  (Thanks Jarrod. . . see
> > > > > >> below)
> > > > > >> The first and last characters of  that regex are for matching the
> > > > > >> responses that have that exact format. (in case there are other
> > > > > >> responses) in the data stream.
> > > > > >> What is important is that the values in the brackets are captured.
>
> > > > > >> We will now need to assosciate these captured values\events to a guage.
> > > > > >> To do this we need to give a guage and the captured event the same join
> > > > > >> numbers.
> > > > > >> In this case 222.
>
> > > > > >> We also need to specify the minimum and maximum values for the guage so
> > > > > >> it is scaled correctly. (in the feedback manager)
> > > > > >> For thisDenonthe volume response range goes from 0 - 98.
>
> > > > > >> I learn as I go so anyone please add what you might think I missed out.
> > > > > >> . . .
>
> > > > > >> xcuse tpyos
>
> > > > > >> Nahshon
>
> > > > > >> On 03/03/2010 01:42, Howard wrote:
>
> > > > > >>> Nahshon - Did you ever do the "how to" tutorial? I am trying to
> > > > > >>> understand how to setup feedback from aDenonAVR to iViewer on an
> > > > > >>> iPod Touch via the broadcaster plugin in Eventghost and having
> > > > > >>> difficulty.
>
> > > > > >>> Howard
>
> > > > > >>> On Jan 19, 11:05 am, Nahshon Williams<spc...@gmail.com>    wrote:
>
> > > > > >>>> Thank you Jarod
>
> > > > > >>>> I now have feedback on the guage.
> > > > > >>>> I am thinking of writing a mini "how to" tutorial when I complete this
> > > > > >>>> project.
> > > > > >>>> There is are little nuances here and there . . .
>
> > > > > >>>> Nahshon
>
> > > > > >>>> Jarrod Bell wrote:
>
> > > > > >>>>> When using hex bytes in the regex, you don't escape the backslash. So
> > > > > >>>>> the regex should be:
> > > > > >>>>> ^MV(\d*)\x0D$
> > > > > >>>>> or
> > > > > >>>>> MV(\d*)\x0D
>
> > > > > >>>>> You would need to copy/paste the string that is being matched against
> > > > > >>>>> into the regex tester within guiDesigner as you cannot enter hex bytes
> > > > > >>>>> into the test value field.
>
> > > > > >>>>> Jarrod
>
> > > > > >>>>> On Jan 19, 3:14 am, Nahshon<spc...@gmail.com>    wrote:
>
> > > > > >>>>>> Just realiased inserted images do not come up on the newsroup
> > > > > >>>>>> hear is a link:
>
> > > > > >>>>>>http://www.vandermehrn.com/lc/feedback/
>
> > > > > >>>>>> On Jan 18, 3:44 pm, Nahshon Williams<spc...@gmail.com>    wrote:
>
> > > > > >>>>>>> Adding Feedback todenonsystem
>
> > > > > >>>>>>> Step one Look at at RS232 protocol spec
> > > > > >>>>>>> <http://vandermehrn.com/lc/AVCA11SR.pdf>
>
> > > > > >>>>>>> The example of a command   *<CR>    is the meaning of 0x0D.
> > > > > >>>>>>>     SIDVD<CR>      :  Select Input source DVD
> > > > > >>>>>>>     MSTHX SURROUND EX<CR>      :  surround Mode Set to THX SURROUND EX
> > > > > >>>>>>>     MVUP<CR>      :  Master Volume UP
> > > > > >>>>>>>     PWON<CR>      :  system PoWer ON
> > > > > >>>>>>>     PWSTANDBY<CR>      :  system PoWer STANDBY
> > > > > >>>>>>>     SI?<CR>    : Request command for now playing input source>>    Return
> > > > > >>>>>>> RESPONSE SI***<CR>
>
> > > > > >>>>>>> This is great I can change volume and Inputs to the system.
> > > > > >>>>>>> here is the Protocol for the AVCA11SR:http://vandermehrn.com/lc/AVCA11SR.pdf
>
> > > > > >>>>>>> What does it say about feedback? Well Page 9 Says:
>
> > > > > >>>>>>> So I write the REGEX and test it.
>
> > > > > >>>>>>> the structure is:
>
> > > > > >>>>>>> MV80\x0D
>
> > > > > >>>>>>> Here are 2 Regexs that can capture the value:
>
> > > > > >>>>>>> ^MV(\d{1,2})\\x0D$
> > > > > >>>>>>> ^MV(\d*)\\x0D$
> > > > > >>>>>>> Both give me a capture of 80
>
> > > > > >>>>>>> So now I enter the FEEDBACK and the ANALOG JOINS (see combined image below)
>
> > > > > >>>>>>> When I change the volume MVUP\x0D or MVDown\x0D
>
> > > > > >>>>>>> Nothing happens to the guage.
>
> > > > > >>>>>>> What am I missing guys?
>
> > > > > >>>>>>> I have been trying feedback for days following my RS232 post.
> > > > > >>>>>>> Look at the indignity of two buttons for Screen up and Screen Down. and
> > > > > >>>>>>> Projector On and Projector Off.
>
> > > > > >>>>>>> Fiasco has a great work around I cannot use for adding 2 commands to a
> > > > > >>>>>>> button. (it needs feedback)
> > > > > >>>>>>> I am reading the manual correctly or missing anything out?
>
> > > > > >>>>>>> I have read it so many times I dream about it seriously....- Hide quoted text -
>
> > > > > >> - Show quoted text -- Hide quoted text -
>
> > > > > - Show quoted text -- Hide quoted text -
>
> > > > - Show quoted text -

--
You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.

Comments

0 comments to "Re: Feedback to Guage on Denon - Now Working"