Tuesday, December 29, 2009

Re: Video for RS232 or any relevant documentation

0 comments
Ouch, that hurts (the socket lockout you mention) and the single
concurrent connection. Glad to know that
before I run into it.

On Dec 29, 10:39 am, xAPPO <thor...@gmail.com> wrote:
> I didn't look up the specific Denon model you are controlling but I
> have my system integrated via a AVR-4306 which has inbuilt Ethernet -
> regardless the RS232 and TCP socket protocol are much the same.  One
> awkward thing about the Denon via TCP is that if a socket is kept open
> it can get locked out for some reason, and if this happens it can't
> reconnect. Only one concurrent connection is supported and so it
> requires that the Denon be power cycled to reset the socket.
>
> Because of this you have to make a choice of either a permanent open
> socket in which case you get real time event information from the
> Denon or an open/close socket approach which avoids the lockouts but
> compromises the event information .  The latter then requires a few
> exchanges each connection to recover state information - or a scape
> from the inbuilt web page.
>
>    K

--

You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.

Comments

0 comments to "Re: Video for RS232 or any relevant documentation"

Post a Comment

 