http://www.io123.no/adapt/html/AHC3000%20Ver%201_6%20User%20Manual.htm
I've no idea of the what the ^A and ^B is. I tried pasting the code as
you wrote it, but its the same. (LED indicates that something is
happening...and nothing happened in telnet either...)
Could it be that I need to "convert" all the " new_state 777 1(\x0A
\x0D) code to HEX (?)
On Dec 10, 2:48 pm, Jarrod Bell <jar...@guilink.com> wrote:
> Hi Even,
>
> What model of hardware is your actual controller?
>
> "Start allways with ^A, end with ^B, space between parameters, max 32
> parameters." - what is ^A and ^B? If it's uppercase A and B then your
> commands would be:
> Anew_state 777 1B\x0A\x0D
>
> Sometimes with devices that are designed for telnet, you need to end
> messages with both a line feed and carriage return (\x0A and \x0D).
>
> We will be eventually adding a debug option to winViewer (which will
> also be able to be used to test iViewer projects), but for now its
> quite simple: whatever you put in your command values is what is sent
> out, with \xFF formatting replaced with the equivalent hex byte (with
> the exception of sliders which can use the slider value within the
> command also).
>
> Without knowing the device protocol, it's a bit hard to help any
> further. Can you link us to a PDF with the full protocol details?
>
> Jarrod
>
> On Dec 11, 12:36 am, deciBel <e...@mangset.no> wrote:
>
> > Hello.
>
> > I'm having a bit of trouble sending the correct commands from CF
> > iViewer to my controller unit.
>
> > To give you the best background information, I've provided my setup
> > for the test that I'm working on:
>
> > System properties:
>
> > My Controller device:
> > IP: 192.168.1.160
> > Port: 10023 (standard port for send/receive commands)
> > TCP
> > Maintain constant connection: Yes
> > Heartbeat managed by system: Yes
> > Rx:
> > Tx:
> > EOM:
> > Connection Join: 0
> > Startup Comand: "None"
>
> > Within this testproject I've made 4 buttons with 4 differenent
> > commands:
>
> > "Testcode1" has a command value: new_state\x0A777\x0A1\x0D
>
> > "Testcode2" has a command value: new_state 777 1\x0D
>
> > "Testcode3" has a command value: 777
>
> > "Testcode4" has a command value: 777\x0D
>
> > If I simulate a command directly from the included software or telnet,
> > for example a button with 2 states. "on" and "off" . This is what It
> > looks like in telnet:
>
> > new_state 777 1 ("enter") (= switch lamp on – only "enter if typed in
> > telnet)
> > (then it gives the feedback: "end 777"
>
> > new_state 777 0 ("enter") (=switch lamp off - only "enter if typed
> > in telnet)
> > (then it gives the feedback "end 777"
>
> > I can see on my controller that it receives "something" when pushing
> > the buttons from iViewer/iPhone. (the LED on my controller indicates
> > that something is happening.) but I can't see anything happening in
> > telnet, or in the software that came with the controller unit.
>
> > I did another test, linking my light switch button to also send an IR
> > signal to my TV at the same changing the channel up and down as the
> > lights went on and off :p . This IR worked fine when I sent it from
> > the software, but nothing happened (at all) from iViewer…
>
> > Abot to get really frustrated now. Feel like I've tried everything.
> > I'm no programming guru, so don't blame me if this is "common sense"
> > I would appretiate any guide, or help in the right direction…
>
> > 1:
> > Do I write my "command values" correctly? If not, what could be wrong?
>
> > 2:
> > Is there any way I can see the commands that are sent? (i.e. a debug
> > window?)
>
> > I've added some information from the Controller unit that I think
> > might be of relevance. (Taken from the manufactures manual)
>
> > Telnet
> > The controller has a telnet server for interpreting commands – connect
> > to controller IP address. The commands are the same as when connecting
> > to the controller through port 10023 as a master program using the
> > server protocol (explained below), except ^A and ^B are omitted at the
> > start and end.
>
> > Server Protocol:
> > Send/receive socket port=10023
>
> > Command stream:
> > Start allways with ^A, end with ^B, space between parameters, max 32
> > parameters.
> > Command names are not case sensitive.
>
> > The following escape sequences are recognized:
> > \\ is replaced with single \
> > \r is replaced with Carriage Return
> > \n is replaced with New Line
> > \" is replaced with single "
> > \t is replaced with TAB
> > \NNN is replaced with character with octal number NNN
> > \xNN is replaced with character with hex number NN
> > \ss is replaced with checksum at this position in string. The checksum
> > is one byte, is initially zero and is from start of string.
> > \sz is replaced with checksum=(256 - (sum&0xff)) at this position in
> > string. The checksum is one byte, is initially zero and is from start
> > of string. This is used when sum of all characters including check sum
> > shall be zero.
> > \sx is replaced with checksum as XOR sum at this position in string.
> > The checksum is one byte, is initially zero and is from start of
> > string.
> > \sy is replaced with checksum as inverted XOR sum at this position in
> > string. The checksum is one byte, is initially zero and is from start
> > of string.
> > \sc is replaced with checksum as CRC16 sum at this position in string.
> > The checksum is two bytes, is initially zero and is from start of
> > string.
> > If character NULL is placed in the string (i.e. \000), this will
> > normally terminate the string except when string is sent to RS232
> > object in binary mode. The character will be replaced with NULL in the
> > RS232 driver.
--
You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.