What PC software are you using to control?
The correct command should be:
1PWR00\x0D
Also try:
1PWR00\x0A\x0D
The last one is what telnet would be sending.
Also make sure you have "maintain constant connection" ticked in the
system properties.
Jarrod
On Dec 17, 8:08 pm, wogboynz <richard.cas...@gmail.com> wrote:
> I am trying to control an Integra 5.9 AV receiver via its TCP port. I
> have set it to the following settings, 1p 192.168.1.17 and port
> 60128.
>
> I have these same settings in the commandfusion software, I can ping
> the receiver from my PC. I think my problem is with the data I am
> sending it, I am not too sure whether it should be hex or not. The
> message to send it for zone 1 off is "1PWR00" with a Carriage Return
> on the end. I have tried converting it to hex and sending the
> following for the zone 1 off command I have tried
> "\x31x50x57x52x30x30x0D" "\x31\x50\x57\x52\x30\x30\x0D" ""1PWR00"/x0D"
> without the quotes except for the ones inside the last example. What
> am I doing wrong?
>
> I can control the unit via my own pc software by sending "1PWR00"
> carriage return.
>
> Any help would be much appreciated, I have control documentation for
> integra codes/protocol etc if anyone wants to take a look at that.
>
> Cheers,
> Richard
--
You received this message because you are subscribed to the Google Groups "CommandFusion" group.
To post to this group, send email to commandfusion@googlegroups.com.
To unsubscribe from this group, send email to commandfusion+unsubscribe@googlegroups.com.
For more options, visit this group at http://groups.google.com/group/commandfusion?hl=en.


Comments
0 comments to "Re: Need help trying to control Integra AV receiver"
Post a Comment