Hi Adam,

With the GC-100, whatever commands you send through to the serial port
are passed through directly to the end device.
So there is nothing you need to add to the commands, just the commands
that the device you are controlling actually expect.

Just remember to connect to the correct TCP port of the GC-100. Serial
port one is TCP port 4999, serial port 2 (if using GC-100-12 or above)
is TCP port 5000.

Jarrod

On Nov 14, 3:07 am, amadcitrus <amadcit...@gmail.com> wrote:
> Hi,
>
> (Thanks for your earlier reply about the IR Jarrod)
>
> I've got a question about RS232 using a GC100-12, should the wizard in
> CF generate the correct format? i.e the 'header' part of the string?
> (given that you have to select which serial port you are sending
> from).
>
> Does anyone have an example rs-232 string (for any device)
> successfully used with the GC100?
> In this instance I am attempting to send some Rako lighting commands
> out of serial port 1, the string would be ho:24 ro:8 sc:4\x0D (house
> number 24, room 8, lighting scene 4)
>
> am i on the right track here.....?
>
> thanks in advance,
> Adam

--